General Information
The P62 and P82 are touchscreen consoles that provide the user interface and machine control functions for the Precor 680, 780, and 880 line of cardiovascular equipment including Treadmills "TRMTreadmill", Elliptical Fitness Crosstrainers™ "EFXElliptical Fitness CrossTrainer®", Adaptive Motion Trainers® "AMTAdaptive Motion Trainer®", Recumbent "RBKRecumbent Bike" and Upright "UBKUpright Bike" bikes.
Both consoles support the Standard Service & Diagnostic menus utilized across Precor cardio machines used by technicians to service and maintain the equipment, see Standard Service Menus. However, there are minor differences in the hardkey and display softkey functionality, see Navigating the Service Menus.
Console system software is easily updated and kept current using a USBShort for Universal Serial Bus, is an industry standard developed in the mid-1990s that defines the cables, connectors and communications protocols used in a bus for connection, communication, and power supply between computers and electronic devices. flash drive connected to the chin USB port used to upload software files. The same chin USB port makes it easy to clone (export/import) system settings and TV Channel Guide mappings between consoles.
These consoles also support the Active Status Light (ASLActive Status Light: Service and maintenance status light. maintenance and machine operating status light. The console provides the user interface, status information, and control functions for the ASL, see Active Status Light (ASL).
The P62/P82 consoles are powered from an external ACAlternating Current: electric current which periodically reverses direction between positive and negative polarity./DCDirect Current: electrical current that only flows in one direction. power adapter plugged into the facility 115 VACvoltage in an alternating current circuit power outlets, except for treadmills. On treadmills, the AC/DC adapter is spliced into the treadmill MCMotor controller or motor controller module input power allowing the console power to be controlled by the treadmill ON/OFF power switch.
ID | Description |
---|---|
Left | |
Right | |
Front | |
Back |
Mechanical single and dual motion controls are used to vary the speed (resistance) and incline levels with values shown on displays located directly above the control. There is also other switches that control the media functions such as volume and TV channels. The P82 also provides an audio headphone jack and USB power supply for charging mobile devices. An LCD touchscreen display provides user workout program control and exercise monitoring information, interface for the Preva™ Network, television (either analog or IPTVInternet Protocol television (IPTV) is a system through which television services are delivered using the Internet protocol suite over a packet-switched network such as a LAN or the Internet, instead of being delivered through traditional terrestrial, satellite signal, and cable television formats. Unlike downloaded media, IPTV offers the ability to stream the media in smaller batches, directly from the source. As a result, a client media player can begin playing the data (such as a movie) before the entire file has been transmitted. This is known as streaming media. Precor supports IPTV thru the 880 line of cardio products including the P82 and P82 with Media Adapter Enseo set-top-box.), and service/maintenance software.
|
|
Motion Control Icons
Each exercise machine type has a unique set of console motion control icons. Depending on the machine type and model, the console can be fitted with either a single or a dual motion control. The icons can also be used to identify which product type the console is designed to work with,
The P82 console cannot be used between different machine product types (i.e. treadmills and AMTs). However, the same P82 can also be used on different product lines within the same product type. For example, a treadmill P82 could be used on either the TRM 700 line or TRM 800 line treadmills.
Motion Control ICONS | Machine Type: ICON Metric(s) |
---|---|
Treadmill (TRM): INCLINE, SPEED |
|
Elliptical (EFX): INCLINE, RESISTANCE | |
AMT: STRIDE HEIGHT, RESISTANCE | |
UBK & RBK bikes: RESISTANCE | |
|
Climber (CLB) : STEP RESISTANCE |
Note: Consoles are specific to a particular cardio machine type and cannot be used on a different type of machine. You can use the motion control icons to determine which machine type the console is designed to work with. |
- P62 I/OInput and Output Interface. Port Diagram, see P62 console.
- P82 I/O Port Diagram, see P82 console.
P82 console
P62 console
CONNECTOR LOCATION |
INTERFACE DESCRIPTION |
CONNECTOR/DEVICE TYPE |
---|---|---|
COMM Data Cable(1) | Black color RJ45 eight pin modular (flat gray Data cable). | |
Ethernet (LAN) Cable(1) | Silver color RJ45 eight pin modular connector (round black LAN cable. | |
E-Stop Switch Cable (TRM Only) |
Six pin strip, keyed. | |
RF (TV) Cable with Isolator | F-Type coax | |
HHHR Sensor Input Cable | Four pin strip, keyed. | |
DC Input Power | Two pin plug (see ) | |
microSD mass storage | .microSD memory card | |
Ferrite cable clamp | The input power cable must be looped thru the ferrite cable clamp. | |
Notes: |
Required repair tools and service items.
Tools/Service Items | Tools/Service Items |
---|---|
US and Metric Hex Key set | 7/16 " RF coax conn torque wrench 2.4 in-lbs (0.271 Nm) |
DVM Multimeter | Compatible heart rate chest strap (supports Polar GymLink) or Precor heart rate chest strap, PN PPP0000AT190012101) |
…Standard and Philips screw driver set |
This table provides a summary of system fasten torque specifications.
System Component | Specification |
---|---|
RF Coax Connector | 2.4 in-lbs (0.271 Nm) |
Plastic Cover Screws | 20 in-lbs (2.3 Nm) |
Flathead Screws | 25 in-lbs (2.8 Nm) |
Console Fasteners | 180 in-lbs (20 Nm |
.
IMPORTANT: Always purchase OEM replacement parts and hardware from Precor. If you use parts not approved by Precor, you could void the Precor Limited Warranty. Use of parts not approved by Precor may cause injury. |
Exploded View Diagram and Parts List
This document provides a copy of the parts Exploded View Diagram and Parts Identification List that you can use as a quick reference, see Parts. It is recommended that servicers go to the Precor Partner website Precor Partner Website to access the most current parts information.
.Wipe down equipment with recommended cleaning solution. Use dry cloth to remove residue solution.
- General: 1 oz. mild soap to 30 oz. water (Ex. Simple Green).
- Console and PVSPersonal Viewing System display.: a diluted solution of one part 91% Isopropyl alcohol to one part water.
|
CAUTION: Do not use acidic cleaners and do not spray directly onto the equipment surfaces. |
Each P82 utilize an external 12 VDC / 50 W power supply.
The power supply AC input is plugged into the facility AC power outlet and the supply output cable is connected to the console power input connector except for treadmills.
For treadmill installations, The power supply input power is hardwired to the line filter output and the earth ground is directly connected to the line filter chassis ground tab (a power supply adapter wire bundle is included with treadmill P82 installations).
|
CAUTION: A maximum of 10 consoles can be connected to one 20-amp dedicated branch circuit. If the branch circuit has any other devices connected, the number of P82 consoles must be reduced by the wattage of the other devices. . |
Input Power
Console input: 12 VDC nominal (range: 8 VDC - 16 VDC), 50 W nominal (60 W max)
Ext Power Supply input: 100 - 240 VAC / 15 or 20 Amp
Earth ground requirements
- Self-powered equipment (EFX, AMT & Bikes): The earth ground is connected from the facility power outlet earth ground through the power supply brick.
- Powered equipment (Treadmills): The power supply input power cables are connected to the line filter output power tabs. The earth ground wire is connected directly to the line filter chassis ground connector tab (a power supply adapter wire bundle is included with treadmill P82 installations).
WARNING: For operator safety and to minimize electrostatic discharge conditions, for AC self-powered equipment, the earth ground must be connected through the power supply brick. |